Fire-Rated Cleanroom Partitions for Modular Building

Catfoss Group Manufacturing

Background: 

As part of an ongoing expansion for an R&D manufacturing campus, Catfoss Group Manufacturing were constructing a modular building and required a number of clean fire-rated areas.

Process:

As an offsite modular construction, site surveys could only be completed once everything was in place on site, where CREST then worked efficiently to complete the necessary surveying and design tasks prior to installation.

Solution:

Working to a tight programme of works, CREST supplied and installed approximately 250m² of fire-rated partitions, 80mm thick Kingspan Mineral Fibre Cored panels were used to create several clean areas with a corridor.

The team also installed 8 no. 60 minute fire-rated double hinged personnel doors, which were compliant to DDA standards. This was in conjunction with firestopping products to the partitions to ensure a fire-rating of up to two hours throughout.

Stancold worked well, especially in the conditions you were working in

Andrew Noble, Catfoss Group Manufacturing
LocationCoventry
Building UseR&D Manufacturing
Panel CoreMineral Fibre
Panel SupplierKingspan
Panel Thickness80mm
Panel Requirements256m²
ServicesProject Management
Site Surveys
Maintenance Advice
Detailed Quotations